Bin No : 350274
Brand: Fluke (USA)
68.500 KWD
(0 review)
Model |
FLUKE 115 |
|
Maximum voltage between any terminal and earth ground |
600 V |
|
Surge protection |
6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 |
|
Display |
Digital: 6,000 counts, updates 4 per second |
|
Bar graph |
33 segments, updates 32 per second |
|
Operating temperature |
-10°C to + 50°C |
|
Storage temperature |
-40°C to + 60°C |
|
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
|
Battery life |
400 hours typical, without backlight |
|
DC millivolts |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
|
DC volts |
Range/resolution |
6.000 V / 0.001 V |
60.00 V / 0.01 V |
||
600.00 V / 0.1 V |
||
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
|
AC millivolts1 True RMS |
Range/resolution |
600.0 mV / 0.1 mV |
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
2.0% + 3 (500 Hz to 1 kHz) |
||
AC volts1 True RMS |
Range/resolution |
6.000 V / 0.001 V |
60.00 V / 0.01 V |
||
600.0 V / 0.1 V |
||
Accuracy |
1.0% + 3 (DC, 45 Hz to 500 Hz) |
|
2.0% + 3 (500 Hz to 1 kHz) |
||
Continuity |
Range/resolution |
600 Ω / 1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of |
|
500 μs or longer. |
||
Ohms |
Range/resolution |
600.0 Ω / 0.1 Ω |
6.000 kΩ / 0.001 kΩ |
||
60.00 kΩ / 0.01 kΩ |
||
600.0 kΩ / 0.1 kΩ |
||
6.000 MΩ / 0.001 MΩ |
||
Accuracy |
0.9% + 1 |
|
Range/resolution |
40.00 MΩ / 0.01 MΩ |
|
Accuracy |
5% + 2 |
|
Diode test |
Range/resolution |
2.00 V / 0.001 V |
Accuracy |
0.9% + 2 |
|
Capacitance |
Range/resolution |
1000 nF / 1 nF |
10.00 μF / 0.01 μF |
||
100.0 μF / 0.1 μF |
||
9999 μF / 1 μF |
||
100 μF to 1000 μF |
||
Accuracy |
1.9% + 2 |
|
Range/resolution |
> 1000 μF |
|
Accuracy |
5% + 20% |
|
Lo-Z capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
|
AC amps True RMS (45 Hz to 500Hz) |
Range/resolution |
6.000 A / 0.001 A |
10.00 A / 0.01 A |
||
Accuracy |
1.5% + 3 |
|
20 A overload for 30-seconds max |
||
DC amps |
Range/resolution |
6.000 A / 0.001 A |
10.00 A / 0.01 A |
||
Accuracy |
1.0% + 3 |
|
20 A overload for 30-seconds max |
||
Hz (V or A input)2 |
Range/resolution |
99.99 Hz / 0.01 Hz |
999.9 Hz / 0.01 Hz |
||
9.999 kHz / 0.001 kHz |
||
50 kHz / 0.01 kHz |
||
Accuracy |
0.1% + 2 |
No reviews yet